Methodology and sources
Every conversion factor, date rule, formula, and primary reference behind mcivf, stated plainly.
Intended purpose and scope
Intended purpose. mcivf.com provides general-purpose calculators and reference information: conversion between units of measurement, calendar arithmetic, arithmetic on numbers entered by the user, descriptions of published grading terms, and a glossary. It is intended for education and personal organisation. It is not intended to provide information for decisions about diagnosis, treatment, monitoring or prevention for any individual, does not process data to produce a clinical interpretation, and is not a medical device.
Scope. To keep it that way, mcivf never shows reference ranges, never labels results, never estimates chances, and never schedules medication.
1. Unit conversion
Molar factors are computed directly from published molecular weights (1000 / MW) without early rounding. Prolactin uses WHO 3rd IS 84/500 (default factor 21.2; configurable in the tool).
- Ferguson J et al. (2020): Establishment of a WHO Reference Reagent for anti-Mullerian hormone. Reprod Biol Endocrinol 2020;18:86. Documents the 140 kDa dimer convention (1 ng/mL = 7.14 pmol/L) and assay calibration differences.
- PubChem (NIH): Molecular weights for Estradiol (CID 5757), Progesterone (CID 5994), 25-OH Vitamin D3 (CID 5283731). Used to derive exact molar conversion factors (1000 / MW).
- Labcorp SI Unit Conversion Table: SI Unit Conversion Table. Cross-check for clinical unit pairs and 1:1 gonadotropin and thyroid unit equivalences.
- Melmed S et al. (2011) & NIBSC 84/500: Endocrine Society Clinical Practice Guideline, JCEM 2011;96(2):273-288; NIBSC IFU 84/500. Basis of the default prolactin factor 1 µg/L = 21.2 mIU/L (WHO 3rd IS 84/500).
2. Transfer dates and due date estimate
All date calculations use integer UTC day arithmetic so daylight-saving transitions never shift dates. The due date estimate follows ACOG Committee Opinion No. 700: transfer date plus (266 minus embryo age), giving +261 days for Day 5 and +263 days for Day 3. Day 6 and Day 7 blastocysts include an optional toggle to count as Day 5 if your clinic uses that convention.
- ACOG Committee Opinion No. 700: Methods for Estimating the Due Date. Obstet Gynecol 2017;129(5):e150-e154 (reaffirmed 2025). ART due date convention: transfer date plus 261 days for a day-5 embryo and 263 days for a day-3 embryo.
- Damewood MD et al.: Disappearance of exogenously administered human chorionic gonadotropin. Fertility and Sterility. Exogenous hCG from a trigger injection can remain detectable for up to about 14 days.
3. hCG arithmetic
For two draws, doubling time uses Δt × ln(2) / ln(h2 / h1) (only when h2 > h1 and both are positive). For three or more positive draws, an ordinary least-squares log-linear fit is computed across elapsed hours.
- Barnhart KT et al. (2016): Differences in Serum Human Chorionic Gonadotrophin Rise in Early Pregnancy by Race and Value at Presentation. Obstet Gynecol 2016. Documents that hCG rise patterns differ by starting concentration and across individuals. mcivf does not display cut-off thresholds.
4. Embryo grading terminology
- ASRM Grading Scales (Gardner scale): Embryo Data Grading and Evaluation: Grading Scales. Reference definitions for blastocyst expansion stages 1 to 6, inner cell mass A to C, and trophectoderm A to C.
- Alpha Scientists and ESHRE (2011): The Istanbul consensus workshop on embryo assessment. Hum Reprod 2011;26(6):1270-1283. Reference terminology for day-3 cell count, fragmentation bands, and multinucleation.
5. Glossary reference
- Zegers-Hochschild F et al. (2017): The International Glossary on Infertility and Fertility Care, 2017 (ICMART). Hum Reprod 2017;32(9):1786-1801. Primary terminology reference for clinical and embryology glossary entries.
6. Regulatory guidance references
- MDCG 2019-11 rev.1 (June 2025): Guidance on Qualification and Classification of Software in Regulation (EU) 2017/745 (MDR) and (EU) 2017/746 (IVDR). EU guidance distinguishing general-purpose calculators from medical device software.
- Swissmedic BW630_30_007e (v3.0): Information sheet: Medical Device Software (effective 21 April 2026). Swissmedic guidance on qualification criteria for software.